The BioShift®  chamber uses ultraviolet C (UV-C) germicidal radiation, which provides an effective and immediate way of deactivating the DNA in bacteria and viruses by destroying their ability to multiply and cause disease.

There are two factors that directly influence the effectiveness of UV-C disinfection: time of exposure and UV-C radiance (intensity). Testing by a nationally recognized laboratory specializing in antimicrobial, biocidal and viricidal effectiveness showed that five minutes of exposure to UV-C radiation in the BioShift® chamber resulted in the elimination of >99.99% of common viruses and bacteria.

Safety features

  • One-button “Start”
  • Two-Emergency “Stop” buttons, located on both sides of the chamber
  • Magnetic doors ensure chamber is securely latched, while allowing for easy opening at the beginning and end of every cycle
  • When the door is open, the BioShift® will not operate
  • Once sterilization in complete, the clean side door can be opened once
  • The sealed chamber protects users from UV radiation
  • Users are protected by a window using glass that is not transparent to UVC radiation
  • The easy-to-use touch screen controller has a countdown timer
  • The touch screen controller allows you to check lamp life, log maintenance reports and more

SPECIFICATIONS

Input Voltage 110-240 V, 50/60 Hz
Operating Power / Current 80W / 670 mA
Standby Power / Current 7W / 100 mA
Germicidal Bulbs / Lamps 20W (4 UV-C lamps)
Weight 125 lbs. (57 kg)
Timer Setting 5:00 minutes
Output 254 nm UV-C light
Initial minimum irradiance 250 mJ/cm2 (300 seconds, cold start)
Operating 65°F (18°C) to 105°F (40.5°C) temperature, 10€“95% humidity
Storage -20°F (-28°C) to 140°F (60°C) temperature, 10€“95% humidity
Ratings IP Rating 50 equivalent, UL Certification

Want More Information?

Talk to a Pro: 1-800-845-3374

SPECIFICATIONS

Input Voltage 110-240 V, 50/60 Hz
Operating Power / Current 80W / 670 mA
Standby Power / Current 7W / 100 mA
Germicidal Bulbs / Lamps 20W (4 UV-C lamps)
Weight 125 lbs. (57 kg)
Timer Setting 5:00 minutes
Output 254 nm UV-C light
Initial minimum irradiance 250 mJ/cm2 (300 seconds, cold start)
Operating 65°F (18°C) to 105°F (40.5°C) temperature, 10€“95% humidity
Storage -20°F (-28°C) to 140°F (60°C) temperature, 10€“95% humidity